Novaa Light Pad Review

We ran it through the WAIT Test™

See how it measures up against other home devices.

Want help understanding which device is right for your pet?
Talk to one of our clinicians.

Written by: Alon Landa
Reviewed: November 2026
Updated: November 2026

Disclosure: MedcoVet makes the Luma, a competing device, and we’re often asked how other home devices compare. MedcoVet isn’t affiliated with NovaaLab. We haven’t bought or tested the Novaa Light Pad: this review uses the company’s published specifications and our labelled arithmetic, and we link our sources so you can check them. It’s part of our Red Light Round Up series; for protocols and condition guidance, see Red Light Therapy for Dogs.

Is the Novaa Light Pad a good at-home light therapy device for pets?

Its 660 nm red and 850 nm near-infrared LEDs are in the bands used in WALT’s draft guidelines for veterinary treatment, and it’s weighted toward near-infrared. But its 120 mW/cm² can’t be the average across the whole pad: over 832 cm², that would be about 100 W of light. Until its figures agree, the WAIT Test™ doesn’t compare its light with WALT’s ranges, and NovaaLab gives no pet instructions.

The WAIT Test™ result

Spec conflict

Its own figures disagree: 120 mW/cm² across the whole 832 cm² pad would be about 100 W of light, which is implausible for a pad like this, so the figure is likely a contact reading over a single LED, not the pad’s average. Until the figures agree, the WAIT Test™ doesn’t compare its light with WALT’s draft ranges or estimate a treatment time, for any condition, animal or coat. NovaaLab gives no pet instructions.

Key Takeaways

  • Its 660 nm red and 850 nm near-infrared are in WALT’s draft bands, with two near-infrared chips in every LED.
  • Its 120 mW/cm² contact reading can’t be the pad’s average: over its 832 cm², that would be about 100 W of light.
  • NovaaLab’s own figures fall to 45 mW/cm² at 1 inch and 25 mW/cm² at 3 inches, and it publishes no average power.
  • It’s a human product with 20-minute sessions and no pet instructions.

Novaa Light Pad specs at a glance

The Novaa Light Pad is a flexible LED pad sold for people, with 150 tri-chip LEDs. The specs come from the NovaaLab help and specifications, as recorded in the WAIT Test™ device comparison (checked Nov 18–19, 2026).

SpecNovaa Light PadSource
Light sourceLED pad (human product), risk group not statedNovaaLab website
Wavelengths150 tri-chip LEDs, each 2 × 850 nm + 1 × 660 nm; power split not publishedNovaaLab website
Average powerNot published—
Irradiance120 mW/cm² at contact (45 at 1 in, 25 at 3 in)NovaaLab website
Treatment head16.3 × 7.9 in (about 832 cm²)NovaaLab website
PulsingNot stated—
How it’s usedPad laid on the body, 20-minute sessions; no pet instructionsNovaaLab website
Price$349.90NovaaLab website

What does the 120 mW/cm² reading cover?

NovaaLab gives 120 mW/cm² at contact, 45 at 1 inch and 25 at 3 inches. If 120 mW/cm² applied evenly across the 832 cm² pad, it would mean about 100 W of light (our arithmetic: 120 × 832), far more than a pad like this gives off. A reading taken right over one LED would explain it. Without an average across the pad, or a total light output, there’s no way to know what a joint under the pad receives.

Not sure which device fits your dog’s condition?

A free consult with a MedcoVet clinician walks you through what your dog needs and what to look for.

Matilda

WAIT Test™ results for the Novaa Light Pad

In short: its wavelengths are in range, but its 120 mW/cm² contact reading can’t be the pad’s average, so the WAIT Test™ doesn’t compare its light with WALT’s ranges. Choose your animal and coat below to see the Spec Check and Pet Check.

  • W · Wavelength (in range): In WALT’s range for red (660 nm) and near-infrared (850 nm).
  • A · Average power (not published): no average power or power per wavelength.
  • I · Irradiance (figures conflict): not compared with WALT’s range until its 120 mW/cm² and its pad size agree.
  • T · Target tissue (partly): the pad is laid on the body without parting the fur; it’s a human product with no pet instructions, and stays in place for 20-minute sessions.
  • Eye safety (partly): an LED pad (human product) with no optical risk group stated.

Pet Check: for a 50 lb dog with a light coat, the hip needs about 45–114 mW/cm² of near-infrared light at the skin. That’s WALT’s draft range of 100–250 mW/cm², adjusted for the roughly 45% of light a light coat lets through (Hochman-Elam 2020). Because its own figures conflict, the WAIT Test™ doesn’t compare its light with that range or estimate a treatment time: every condition reads Spec conflict, for every coat. The results are the same for the 10 lb cat. Under a black coat, too little light would get through over the joints and spine in any case, so clip or shave the area first, with your vet’s guidance.

All devices × conditions at a glance

Each cell compares the device’s light with WALT’s irradiance range for that target, at the skin under your pet’s coat (Pet Check, step 2). The first five columns are the Spec Check, which assumes a light coat. Pick a device name or a cell to open it above.

TargetLight WALT’s draft range needs at the skin (light coat)
Wounds on clipped skin30–100 mW/cm² (clipped, so no coat adjustment)
Most joints through a light coatAbout 23–45 mW/cm² (WALT’s 50–100 through a light coat)
Hip through a light coatAbout 45–114 mW/cm² (WALT’s 100–250 through a light coat)

A device’s own irradiance never goes up. The coat only changes how much of its light reaches the skin. See WALT’s draft dosing guidelines.

Which Novaa Light Pad wavelengths count?

WALT’s draft guidelines name two bands for continuous light: 630–690 nm red for superficial targets and 780–860 nm near-infrared for deeper ones. WALT notes red light may be unsuitable for targets deeper than 1–2 cm (WALT).

WALT red 630–690WALT near-infrared 780–860660 nm850 nmNovaa Light Pad wavelengths below the bar; dark = inside a WALT band.
  • 660 nm red falls inside WALT’s red band, the right kind of light for wounds and other surface problems.
  • 850 nm near-infrared falls inside WALT’s near-infrared band, the light WALT’s draft doses use for hips, elbows, knees and the spine.
  • Two near-infrared chips per LED. That suggests more near-infrared than red, but chip counts don’t give the power split.

Why irradiance matters as much as dose

WALT’s draft guidelines give a dose (J/cm²) and an irradiance range (mW/cm²). The same dose delivered at a very different irradiance doesn’t reliably give the same result (Huang 2009). Irradiance is power divided by the area the light falls on. A longer session hasn’t been shown to make up for irradiance that’s too low, and a short session at very high irradiance isn’t the same either. Think of roasting a turkey: below a certain oven temperature, more hours don’t cook it.

Does the Novaa Light Pad work through fur?

WALT’s doses assume an unclipped light coat, and WALT’s guidelines don’t cover shaved skin or dark or black coats. For those we use a 2020 study of 47 dogs that measured how much light passes through the skin and coat (Hochman-Elam 2020). The coat figures below are MedcoVet’s estimates from that study, not WALT’s. The pad is laid on the coat and doesn’t part the fur, so the coat applies in full. Its own figures show how quickly its light falls off with distance: from 120 mW/cm² at contact to 25 at 3 inches, so a thick coat that holds the pad off the skin costs it light too. We don’t have a photo of the Novaa Light Pad in use on a pet that we can use here, so the table carries this section.

CoatShare of the device’s light reaching the skin
ShavedAll of it
LightAbout 45%
Dark brownAbout 15%
BlackNot compared: clip or shave first, with your vet’s guidance

How it’s used, and what that does to the dose

NovaaLab sells the pad for people, with 20-minute sessions, and gives no instructions for pets. WALT’s draft guideline is written per spot: a dose held for a set time at each placement.

  • Human timings. A 20-minute human session isn’t a veterinary dose.
  • Contact varies. A pad on a curled-up or moving pet doesn’t sit evenly against the coat.
  • No figures to dose from. With no average irradiance, there’s no way to work out a dose per spot.

What the Novaa Light Pad does well

  • Weighted toward near-infrared. Each tri-chip LED has two 850 nm chips and one 660 nm chip, all inside WALT’s draft bands.
  • Irradiance at three distances. NovaaLab publishes readings at contact, 1 inch and 3 inches, which shows how quickly its light falls off.
  • A large pad. At about 832 cm², it covers a wide area at once.

What would change this result

We’d look again if NovaaLab published an irradiance map across the pad (not just over one LED), its average optical output by wavelength, and guidance for pets. Once its figures agree, the WAIT Test™ could compare its light with WALT’s ranges.

When NOT to use red light therapy

Red light therapy supports a vet-guided plan; it doesn’t replace a diagnosis. Keep the light away from the eyes, yours and your pet’s. Don’t use any device over the eyes, over a known or suspected tumor, or on sudden pain, paralysis or loss of bladder control: see a vet now. For how veterinary light devices are regulated, see FDA and veterinary devices.

How the Luma compares

The Luma is MedcoVet’s own device, so judge this section with that in mind. On the WAIT Test™ device comparison, the Luma is held to the same rules: it has both 635 nm red and 850 nm near-infrared in WALT’s bands, and it publishes its power, its split and its head size (1,010 mW over 14.5 cm², about 70 mW/cm², of which 606 mW is near-infrared). Its fur-parting comb is credited as reaching the skin, which is a MedcoVet assumption until it’s measured.

Want to know if light therapy fits your dog? Take the 2-minute quiz.

Sprite

Clinical summary

Mechanism

Red and near-infrared light can influence cell signaling linked to inflammation, circulation and tissue repair, when enough light in the right band reaches the tissue.

Evidence level

Moderate for select pain, inflammation and healing uses at adequate doses. No veterinary study of the Novaa Light Pad itself is cited. For this device, the dose reaching the tissue can’t be worked out from its published figures.

When it works best

Small surface problems and shallow joints, on clipped or thin-coated skin, with modest expectations until its output at the skin is known.

When not to use

Over the eyes, over known or suspected cancer, on active infections that need medical care, or in place of a veterinary diagnosis.

Limitations

This review uses the company’s published figures; we haven’t tested the Novaa Light Pad.

Novaa Light Pad questions Pet Parents ask

Spec conflict for every condition, for dogs and cats: 120 mW/cm² across the whole 832 cm² pad would be about 100 W of light, so the figure is likely a single-LED reading.

660 nm red and 850 nm near-infrared, with two near-infrared chips and one red chip in each of its 150 LEDs.

That timing is for people. Ask your vet about your pet’s condition and a suitable device and protocol.

It doesn’t part the fur. A light coat lets about 45% of a device’s light through and a dark brown coat about 15%; under a black coat, clip or shave first, with your vet’s guidance.

Its near-infrared is in the band WALT uses for deeper targets, but its figures don’t show how much reaches them. Ask your vet what fits your pet’s diagnosis.

No. Without an average irradiance across the pad, a session time can’t be turned into a dose.

No. This review uses NovaaLab’s published figures. If it publishes an irradiance map, or an independent measurement becomes available, we’ll update it.

How we checked, and sources

We took the Novaa Light Pad’s specifications from the company’s published pages, as recorded in the WAIT Test™ device comparison (checked Nov 18–19, 2026). We haven’t tested it.

Ready to talk through your dog’s plan?

Book a free consult with a MedcoVet clinician.

Spock

Evidence Citations

  • Biphasic dose response in low level light therapy

    By Huang YY; Chen ACH; Carroll JD; Hamblin MR

    • 2009

    • Journal: Dose-Response

    Abstract: Review describing the biphasic dose-response phenomenon in photobiomodulation, where lower doses may stimulate repair while excessive doses can reduce or inhibit benefit.

    One Sentence Outcome: Supports careful dosing by showing that PBM response depends strongly on treatment dose and parameters.

    Study Parameters: Review of mechanistic, animal, and clinical evidence for a biphasic dose response in photobiomodulation.

    Device Parameters: Reviews wavelength, fluence, irradiance, pulse structure, and treatment timing in low-level light therapy.

    Evidence Level: Narrative review

    Study Type: Review

    Outcome Direction: Parameter / dosing review

  • Effects of laser power, wavelength, coat length, and coat color on tissue penetration using photobiomodulation in healthy dogs.

    By Hochman-Elam et al.

    • 2020

    • Journal: Can J Vet Res

    Abstract: This canine penetration study found significantly lower light transmission in darker and unshaved areas, indicating that fur and pigmentation materially affect how much therapeutic light reaches tissue.

    One Sentence Outcome: Laser power, wavelength, coat color and shaving changed how much light got through; coat length did not.

    Study Parameters: Experimental veterinary study measuring tissue penetration under varying laser power, wavelength, coat length, and coat color conditions.

    Device Parameters: Laser power and wavelength varied across shaved/unshaved and different coat-color conditions to evaluate transmission through canine tissue/coat barriers.

    Evidence Level: Experimental veterinary study

    Study Type: Experimental veterinary study

    Outcome Direction: Mechanistic / supportive

🐾 Ready to Take the Next Step?
Whether you’re just learning or ready to act — we’ve got you.

👉 Book a Free Consult
 Talk to a licensed clinician about your pet’s condition and get a personalized plan. No pressure, just real help.

👉Learn More About the Luma
 Explore how our at-home red light therapy device works, why it’s different, and what it can do for your pet.

Alon Landa, CEO and co-founder of MedcoVet

About the Author
Alon Landa is the CEO and co-founder of MedcoVet, a leader in at-home red light therapy for pets. With over 20 years of experience in medical technology and firsthand involvement in developing the Luma, Alon combines deep technical knowledge with a passion for improving pet health. He regularly collaborates with veterinarians and pet parents to advance photobiomodulation (PBM) care at home.
 📍 Based in Boston, MA
📖Read more from Alon here

Similar Posts

Leave a Reply

Your email address will not be published. Required fields are marked *